MEASure:VOLTage? Reads the measured output voltage. Returns a 6 digit string.

SCPI Command Syntax GEN Command Syntax

MEASure:VOLTage?

MV?

Parameters

None

Default Suffix

V

Returned Parameters

MEASure:POWer? Reads the measured output power. Returns a 6 digit string.

SCPI Command Syntax GEN Command Syntax

MEASure:POWer?

MP?

Parameters

None

Default Suffix

W

Returned Parameters

7.12.6 DISPlay Subsystem DISPlay:STATe Turns front panel voltage and Current display toggle On or Off.

SCPI Command Syntax GEN Command Syntax

DISPlay[:WINDow]:STATe

none

Parameters Examples Query Syntax

0|OFF 1|ON

DISP:STAT 1 DISP:STAT OFF DISPlay[:WINDow]:STAT?

Returned Parameters

0 |1

DISPlay:FLASh Makes front panel voltage and Current displays flash.

SCPI Command Syntax GEN Command Syntax

DISPlay[:WINDow]:FLASh

none

Parameters Examples

0|OFF 1|ON

DISP:FLASh 1 DISP:FLASh OFF

106