TDK Lambda | Z+Low Voltage User Manual
CURRent:MODE This command selects FIX, LIST, WAVE subsystems control over the power supply output current.
SCPI Command Syntax GEN Command Syntax
[SOURce]:CURRent:MODE
None
Parameters *RST Value Examples Query Syntax
NONE | FIXed | LIST | WAVE
NONE
CURR:MODE LIST CURR:MODE FIX
[SOURce]:CURRent:MODE? NONE | FIX | LIST | WAVE
Returned Parameters
CURRent:TRIGger Programs the pending triggered current level of the power supply. The pending triggered current level is a stored value that is transferred to the output terminals when a trigger occurs.
SCPI Command Syntax GEN Command Syntax
[SOURce]:CURRent[:LEVel]:TRIGger[:AMPLitude]
None
Default Suffix
A
Examples
CURR:TRIG 3200 MA CURR:LEV:TRIG 3.2
Query Syntax
[SOURce]:CURRent[LEVel]:TRIGger [:AMPLitude]?
Returned Parameters
NOTE: CURR:MODE LIST and WAVE are an implied ABORt command. Only the last sent command can be accepted as WAVE or LIST. Previous mode reverts to NONE.
7.12.5 Measure Subsystem This subsystem reads the actual voltage and current. The power is a result of multiplying voltage and current measurements. MEASure:CURRent? Reads the measured output current. Returns a 6 digit string.
SCPI Command Syntax GEN Command Syntax
MEASure:CURRent?
MC?
Parameters
None
Default Suffix
A
Returned Parameters
105
Made with FlippingBook Annual report maker