TDK Lambda | Z+Low Voltage User Manual

VOLTage:PROTection:LOW Sets the under voltage protection (UVP) level of the power supply.

SCPI Command Syntax GEN Command Syntax

[SOURce]:VOLTage:PROTection:LOW

UVL < NRf+> , UVP < NRf+>

Default Suffix

V 0

*RST Value Examples

VOLT:PROT:LOW 2.5 VOLT:PROT:LOW MAX [SOURce]:VOLTage:PROTection:LOW [:LEVel]? VOLT:PROT:LOW? MIN; VOLT:PROT:LOW? MAX

Query Syntax

VOLT:PROT:LOW? returns presently programmed UVP level. VOLT:PROT:LOW? MAX and VOLT:PROT:LOW? MIN returns the maximum and minimum programmable UVP levels.

Returned Parameters

NOTE: VOLT:PROT:LOW MAX set UVP level maximum 5% below voltage value

VOLTage:TRIGger Programs the pending triggered voltage level of the power supply. The pending triggered voltage level is a stored value that is transferred to the output terminals when a trigger occurs.

SCPI Command Syntax GEN Command Syntax

[SOURce]:VOLTage[:LEVel]:TRIGger [:AMPLitude]

None

Default Suffix

V

Examples

VOLT:TRIG 1200 MV VOLT:LEV:TRIG 1.2

Query Syntax

[SOURce]:VOLTage[:LEVel]:TRIGger [:AMPLitude]?

VOLT:TRIG? returns the presently programmed voltage level. If the VOLT:TRIG level is not programmed, the default value is 0V.

Returned Parameters

7.12.4 Current Subsystem This subsystem programs the output current of the power supply. CURRent Sets the output current value in Amperes. The range of current values are described in Tables 7-6, 7-7 and 7-8. The maximum number of characters is 12.

SCPI Command Syntax GEN Command Syntax

[SOURce]:CURRent[:LEVel] [:IMMediate][:AMPLitude]

PC PC?

Default Suffix

A 0

*RST Value Examples

CURR 500 MA CURR:LEV .5

[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]? [SOURce]:CURRent? MAX [SOURce]:CURRent? MIN

Query Syntax

CURR? returns the present programmed current level. CURR? MAX and CURR? MIN returns the maximum and minimum programmable current levels.

Returned Parameters

104

Made with FlippingBook Annual report maker