TDK Lambda | Z+Low Voltage User Manual

NOTE: VOLT:MODE LIST and WAVE is an implied ABORT command. WAVE mode cannot be programmed simultaneously for bothVoltage and Current. Only the last sent command can be accepted asWAVE. Previous mode reverts to NONE.

VOLTage:PROTection:LEVel Sets the OVP level. The OVP setting range is given inTable 7-9. The number of characters after OVP is up to 12. The minimum setting level is approx. 105% of the set output voltage, or the value in Table 7-9, whichever is higher.

SCPI Command Syntax GEN Command Syntax

[SOURce]:VOLTage:PROTection:LEVel

OVP < NRf+>

Default Suffix

V

*RST Value Examples

MAX

VOLT:PROT:LEV 2.5

[SOURce]:VOLTage:PROT:LEV? VOLT:PROT:LEVel? MIN VOLT:PROT:LEVel? MAX

Query Syntax

VOLT:PROT:LEV? returns presently programmed OVP level. VOLT:PROT:LEV? MAX and VOLT:PROT:LEV? MIN return the maximum and minimum programmable OVP levels.

Returned Parameters

NOTE: VOLT:PROT:LEV MIN set OVP level 5% above voltage set value

VOLTage:PROTection:LOW:STATe Sets the under voltage protection (UVP) status of the power supply. If the UVP status selected, then the under voltage protection is enabled.

SCPI Command Syntax GEN Command Syntax

[SOURce]:VOLTage:PROTection:LOW:STATe

UVL < NRf+> , UVP < NRf+>

Parameters *RST Value Examples Query Syntax

UVL|UVP

UVL

VOLT:PROT:LOW:STAT UVP

[SOURce]:VOLTage:PROTection:LOW :STATe?

Returned Parameters

UVP|UVL

103

Made with FlippingBook Annual report maker