TDK Lambda | Z+Low Voltage User Manual
NOTE: VOLT:MODE LIST and WAVE is an implied ABORT command. WAVE mode cannot be programmed simultaneously for bothVoltage and Current. Only the last sent command can be accepted asWAVE. Previous mode reverts to NONE.
VOLTage:PROTection:LEVel Sets the OVP level. The OVP setting range is given inTable 7-9. The number of characters after OVP is up to 12. The minimum setting level is approx. 105% of the set output voltage, or the value in Table 7-9, whichever is higher.
SCPI Command Syntax GEN Command Syntax
[SOURce]:VOLTage:PROTection:LEVel
OVP < NRf+>
Default Suffix
V
*RST Value Examples
MAX
VOLT:PROT:LEV 2.5
[SOURce]:VOLTage:PROT:LEV? VOLT:PROT:LEVel? MIN VOLT:PROT:LEVel? MAX
Query Syntax
Returned Parameters
NOTE: VOLT:PROT:LEV MIN set OVP level 5% above voltage set value
VOLTage:PROTection:LOW:STATe Sets the under voltage protection (UVP) status of the power supply. If the UVP status selected, then the under voltage protection is enabled.
SCPI Command Syntax GEN Command Syntax
[SOURce]:VOLTage:PROTection:LOW:STATe
UVL < NRf+> , UVP < NRf+>
Parameters *RST Value Examples Query Syntax
UVL|UVP
UVL
VOLT:PROT:LOW:STAT UVP
[SOURce]:VOLTage:PROTection:LOW :STATe?
Returned Parameters
UVP|UVL
103