TDK Lambda | Z+Low Voltage User Manual

7.12.2 Instrument Subsystem The subsystem programs one or more power supplies. from 1 to 31. INSTrument:COUPle

SCPI Command Syntax GEN Command Syntax

INSTrument:COUPle

None

Parameters

ALL|NONE

INSTrument:NSELect

SCPI Command Syntax GEN Command Syntax

INSTrument:NSELect

ADR n (single address) INSTrument:NSELect 6 INSTrument:NSELect?

Examples

Query Syntax

7.12.3 Voltage Subsystem VOLTage Sets the output voltage value in Volts. The range of voltage values are described in Table 7-5. The maximum number of characters is 12.

SCPI Command Syntax GEN Command Syntax

[SOURce]:VOLTage[:LEVel] [:IMMediate][:AMPLitude]

PV < NRf+> PV?

Default Suffix

V 0

*RST Value Examples

:VOLT 500 MV

VOLT:LEV 234.56789

[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]? VOLTage? MAX VOLTage? MIN

Query Syntax

VOLT? returns the present programmed voltage level. VOLT? MAX and VOLT? MIN returns the maximum and minimum programmable voltage levels.

Returned Parameters

VOLTage:MODE This command selects FIX, LIST, WAVE subsystems control over the power supply output voltage.

SCPI Command Syntax GEN Command Syntax

[SOURce]:VOLTage:MODE

None

Parameters *RST Value Examples Query Syntax

NONE | FIXed | LIST | WAVE

NONE

VOLT:MODE LIST VOLT:MODE FIX

[SOURce]:VOLTage:MODE? NONE | FIX | LIST | WAVE

Returned Parameters

102

Made with FlippingBook Annual report maker