TDK Lambda | Z+Low Voltage User Manual
OUTPut:TTLTrg:MODE Sets the operation of the Trigger Out signal to either OFF, Function Strobe or Trigger mode. Programming Mode NONE, FIX: • In TRIG mode, trigger is generated when output status changes. • In Function Strobe mode, an output pulse is generated automatically any time an output parameter such as output, voltage or current is programmed. Programming modes LIST or WAVE: • In TRIG mode, trigger is generated when LIST or WAVE is completed. • InFunctionStrobemode, anoutputpulse isgeneratedautomaticallyany timea step is completed. The power supply Trigger Out signal is available at J3-3 connector on the rear panel.
SCPI Command Syntax GEN Command Syntax
OUTPut:TTLTrg:MODE
None
Parameters *RST Value Examples Query Syntax
TRIG| FSTR|OFF
OFF
OUTP:TTLT:MODE TRIG
OUTP:TTLT:MODE?
Returned Parameters
OUTPut:RELay1(2):STATe Sets pin J3-1 (1) and J3-6 (2) state. The ON parameter is according to low level.
SCPI Command Syntax GEN Command Syntax
OUTPut:RELay1(2)[:STATe]
REL1(2)
Parameters *RST Value Examples Query Syntax
0|OFF 1|ON
1
OUTP:REL1(2) 1 OUTP:REL1(2) ON
OUTPut:REL1(2)[:STATe]?
Returned Parameters
0|1
OUTPut:MODE? Returns the power supply operation mode. When the power supply is On (OUT 1) it will return ”CV” or ”CC”. When the power supply is OFF (OUT 0) it will return ”OFF”.
SCPI Query Syntax GEN Query Syntax Returned Parameters
OUTPut:MODE?
MODE?
101