TDK Lambda | Z+Low Voltage User Manual

OUTPut:TTLTrg:MODE Sets the operation of the Trigger Out signal to either OFF, Function Strobe or Trigger mode. Programming Mode NONE, FIX: • In TRIG mode, trigger is generated when output status changes. • In Function Strobe mode, an output pulse is generated automatically any time an output parameter such as output, voltage or current is programmed. Programming modes LIST or WAVE: • In TRIG mode, trigger is generated when LIST or WAVE is completed. • InFunctionStrobemode, anoutputpulse isgeneratedautomaticallyany timea step is completed. The power supply Trigger Out signal is available at J3-3 connector on the rear panel.

SCPI Command Syntax GEN Command Syntax

OUTPut:TTLTrg:MODE

None

Parameters *RST Value Examples Query Syntax

TRIG| FSTR|OFF

OFF

OUTP:TTLT:MODE TRIG

OUTP:TTLT:MODE?

Returned Parameters

OUTPut:RELay1(2):STATe Sets pin J3-1 (1) and J3-6 (2) state. The ON parameter is according to low level.

SCPI Command Syntax GEN Command Syntax

OUTPut:RELay1(2)[:STATe]

REL1(2)

Parameters *RST Value Examples Query Syntax

0|OFF 1|ON

1

OUTP:REL1(2) 1 OUTP:REL1(2) ON

OUTPut:REL1(2)[:STATe]?

Returned Parameters

0|1

OUTPut:MODE? Returns the power supply operation mode. When the power supply is On (OUT 1) it will return ”CV” or ”CC”. When the power supply is OFF (OUT 0) it will return ”OFF”.

SCPI Query Syntax GEN Query Syntax Returned Parameters

OUTPut:MODE?

MODE?

CV|CC|OFF

101