TDK Lambda | Z+Low Voltage User Manual

OUTPut:PROTection:FOLDback Foldback mode is used to disable the output when a transition is made between the operation modes. The power supplywill turn off the output after a specified delay if the power supplymakes transition into CV mode or into CC mode. This feature is particularly useful for protecting current or voltage sensitive loads.

SCPI Command Syntax GEN Command Syntax

OUTPut:PROT:FOLDback[:MODE]

FLD

Parameters *RST Value Examples Query Syntax

OFF|0, CC|1, CV|2 .

OFF

OUTPut:PROT:FOLDback[:MODE] CC OUTPut:PROT:FOLDback[:MODE]?

Returned Parameters

OUTPut:PROTection:DELay Sets the delay time between the programming of an output change that produces a CV or CC status condition. This command applies to UVP and Foldback functions.

SCPI Command Syntax GEN Command Syntax

OUTPut:PROTection:DELay

FBD

Parameters

0.1 to 25.5|MIN|MAX (step 0.1s)

Unit

S (second)

*RST Value Examples

0mS

OUTPut:PROTection:DELay 2E-1 OUTPut:PROTection:DELay?

Query Syntax

Returned Parameters

OUTPut:ILC:MODE Selects the mode of operation of the Remote Inhibit protection. In OFF mode the power supply ignores J3-4 (ILC) status.

SCPI Command Syntax GEN Command Syntax

OUTPut:ILC:MODE

RIE

Parameters *RST Value Examples Query Syntax

0|OFF 1|ON

OFF

OUTPut:ILC:MODE ON OUTPut:ILC:MODE?

Returned Parameters

ON/OFF

100