TDK Lambda | Z+High Voltage User Manual
LIST:CURRent Specifies theoutput current points ina list.The current points aregiven in the commandparameters, which are separated by commas.
SCPI Command Syntax
[SOURce]:LIST:CURRent
Default Suffix
A
Examples
LIST:CURR 2.5,3.0,3.5 LIST:CURR MAX,2.5,MIN
up to 12 parameters
Query Syntax
LIST:CURRent?
Returned Parameters
2.5,3.0,3.5
LIST:LOAD Loads from memory LIST type. Type voltage/current values, dwell values, STEP parameter and counter specified in stored numbers <1..4>
SCPI Command Syntax
[SOURce]LIST:LOAD
Examples
LIST:LOAD 3
LIST:DWELl Specifies the time interval that each value (point) of a list is to remain in effect.
SCPI Command Syntax
[SOURce]:LIST:DWELI
Range
0.001 to 129,600 seconds
Default Suffix
S
Examples
LIST:DWEL .6,1.5,1.5,.4
up to 12 parameters
CURR:MODE LIST:COUN LIST:CURR LIST:STEP LIST:VOLT VOLT:MODE
Related Commands
Query Syntax
LIST:DWEL? .6,1.5,1.5,.4
Returned Parameters
LIST:STEP Determines if a trigger causes a list to advance only to its next point or to sequence through all the points. • LIST:STEPAUTO -When triggered, it createswaveforms consecutively, until the list is completed. • LIST:STEP ONCE - When triggered, it executes one step from the list.
SCPI Command Syntax
[SOURce]:LIST:STEP
Parameters
AUTO | ONCE
*RST
AUTO
Examples
LIST:STEP ONCE
Query Syntax
[SOURce]:LIST:STEP?
Returned Parameters
AUTO | ONCE
108