LIST:CURRent Specifies theoutput current points ina list.The current points aregiven in the commandparameters, which are separated by commas.

SCPI Command Syntax

[SOURce]:LIST:CURRent {,}

Default Suffix

A

Examples

LIST:CURR 2.5,3.0,3.5 LIST:CURR MAX,2.5,MIN

up to 12 parameters

Query Syntax

LIST:CURRent?

Returned Parameters

2.5,3.0,3.5

LIST:LOAD Loads from memory LIST type. Type voltage/current values, dwell values, STEP parameter and counter specified in stored numbers <1..4>

SCPI Command Syntax

[SOURce]LIST:LOAD

Examples

LIST:LOAD 3

LIST:DWELl Specifies the time interval that each value (point) of a list is to remain in effect.

SCPI Command Syntax

[SOURce]:LIST:DWELI {,}

Range

0.001 to 129,600 seconds

Default Suffix

S

Examples

LIST:DWEL .6,1.5,1.5,.4

up to 12 parameters

CURR:MODE LIST:COUN LIST:CURR LIST:STEP LIST:VOLT VOLT:MODE

Related Commands

Query Syntax

LIST:DWEL? .6,1.5,1.5,.4

Returned Parameters

LIST:STEP Determines if a trigger causes a list to advance only to its next point or to sequence through all the points. • LIST:STEPAUTO -When triggered, it createswaveforms consecutively, until the list is completed. • LIST:STEP ONCE - When triggered, it executes one step from the list.

SCPI Command Syntax

[SOURce]:LIST:STEP

Parameters

AUTO | ONCE

*RST

AUTO

Examples

LIST:STEP ONCE

Query Syntax

[SOURce]:LIST:STEP?

Returned Parameters

AUTO | ONCE