TDK Lambda | Z+Low Voltage User Manual

5.9 Parameter Setting Memory Power Supply has four memory configuration modes:

Subsystem Level

Function Level

Display

Display Parameter Level Display

Description

Save setting in non violate memory Recall setting in non violate memory

SAVE

1…4 1…4

 

   

RECALL

Memory



RST

YES YES

Reset setting



Set factory default setting

FRST



Table 5-6: Parameter Setting Memory

5.9.1 Default Setting For factory default parameters refer to Table 5-7. 1. Press MENU button. MENU (green) LED illuminates. ”  ” message appears on the Voltage display. 2. Rotate Voltage encoder until ”  ” message appears on Voltage display. 3. Press Voltage encoder. ”  ” message appears on Voltage Display. 4. Rotate Voltage encoder until ” . ” message appears on Voltage display. 5. Press Voltage encoder. ” . ”message appears on VoltageDisplay, and ”  ” appears onCurrent display . 6. Press the Current encoder ”  ” Message appears on the display for 1sec. The display blinks once and returns to previous level. 7. Press MENU button twice to return display to previous state, MENU LED turns OFF.

NOTE: No response for FRST command. After this command the power supply loses communicationbecause of communication setting change.

5.9.2 Reset For Reset parameters refer to Table 5-7. 1. Press MENU button. MENU (green) LED illuminates. ”  ” message appears on the Voltage display. 2. Rotate Voltage encoder until ”  ” message appears on Voltage display. 3. Press Voltage encoder. ”  ” message appears on Voltage Display. 4. Rotate Voltage encoder until ”  ” message appears on Voltage display. 5. Press Voltage encoder. ”  ” message appears on Voltage Display. ”  ” appears on the Current display . 6. Press the Current encoder, display blinks and returns to previous level. 7. Press MENU button twice to return display to previous state, MENU LED turns OFF.

5.9.3 Last Setting Memory Memory stores last set parameters when AC switch is turned off. For last set parameters refer to Table 5-7.

73