3.9.7 Connecting Single Loads, Local Sensing (default) Fig.3-6 shows recommended load and sensing connections for a single load. The local sense lines shown are default connections at the rear panel J2 sense connector. Local sensing is suitable for applications where load regulation is less critical.
Load lines, twisted pair, shortest length possible.
+V -V
+ -
Load
Power Supply
-Rem. sense -Local sense +Rem. sense +Local sense
Fig.3-6: Single load connection, local sensing
3.9.8 Connecting Single Loads, Remote Sensing Fig.3-7 shows recommended remote sensing connection for single loads. Remote sensing is used when, in Constant Voltage mode, the load regulation is important at the load terminals. Use twisted or shielded wires to minimize noise pick-up. If shielded wires are used, the shield should be connected to the ground at one point, either at the power supply chassis or the load ground. The optimal point for the shield ground should be determined by experimentation.
Load lines. Twistedpair shortest lengthpossible.
+V -V
+ -
Load
Power Supply
Sense lines. Twisted pair or shielded.
-Rem. sense -Local sense +Rem. sense +Local sense
Fig.3-7: Remote sensing, single load