TDK Lambda | Z+Low Voltage User Manual

CAUTION: Ensure that the loadwiringmountinghardwaredoes not short theoutput terminals. Heavy connecting cables must have some form of strain relief to prevent loosening the connections or bending the bus-bars. 10V to 100V Models Refer to Fig.3-4 for connection of the load wires to the power supply bus-bars and to Fig.3-5 for mounting the bus-bars shield to the chassis.

Fig. 3-4: Load wires connection, 10V to 100V models.

PT SCREW KA40x8 WN1412 (2 PLACES)

INSERT THE SNAP HOOKS INTO THE DEDICATED HOLES IN THE BUS BARS.

output connectors protection

BUS BARS PROTECTION (PROVIDED IN THE PACKAGE)

Fig. 3-5: Bus-bars shield mounting

60V, 100V Models

WARNING: There is a potential shock hazard when using a power supply with an output voltage greater than 60VDC. Do not turn ON power supply when output voltage is above 60VDCwithout output bus-bars and output connectors protection assembled. Ensure that theprotectionof outputbus-bars andoutput connectors ismountedandproperlyassembled, and that the bus bar protection is locked by two PT type screws as described in Fig. 3.5

42