TDK Lambda | Z+Low Voltage User Manual

Subsystem Commands

SCPI Command

Description

GEN Command

ABORt DISPlay

Aborts the triggered action

[:WINDow]:STATe [:WINDow]:FLASh

Display ON/OFF

Display Flash

GLOBal

:CURRent

:[AMPLitude]

Set the output current for all power supplies

GPC

:VOLTage

:[AMPLitude]

Set the output voltage for all power supplies Enables/disables the all power supplies output

GPV

:OUTPut:STATe

GOUT GRCL GRST GSAV

*RCL {1|2|3|4}

Recall setting for all power supplies

*RST

Reset all power supplies

*SAV {1|2|3|4}

Save settings for all power supplies

INITiate

[:IMMediate]

Trigger initiate

:CONTinuous

Enable/disable continuously trigger

INSTrument

Couple for all Z + power supplies

:COUPle ALL|NONE

:NSELect

Select the power supply for communication

ADR

MEASure

:CURRent[:DC]? :VOLTage[:DC]? :POWer[:DC]?

Returns the measured output current Returns the measured output voltage Returns the measured output power

MC? MV? MP?

OUTPut

[:STATe]

Enables/disable the supply output

OUT[?]

:PON

[:STATe]

Programs the Power-ON state

AST[?]

:PROTection :CLEar

Resets latched protection

:FOLDback

[:MODE] OFF|CC|CV

Set operation protection mode

FLD[?] FBD[?]

:DELay

Set protection delay

:ILC

:MODE

Enables/disable analog output ON/OFF control

RIE[?]

:TTLTrg

:MODE OFF|FSTR|TRIG

Set output trigger mode

116

Made with FlippingBook Annual report maker