TDK Lambda | Z+High Voltage User Manual
4.3.2 J3 Connector Terminal and Function Control and monitoring signals are isolated from the power supply output.
Connector Technical Information • Connector type: 43650-0801, MOLEX. • Receptacle type: 43645-0800, MOLEX. • Contact pins: 43030-0002, MOLEX. • Hand tool: 63819-0000, MOLEX. • Wire: AWG 20-24
8 7 6 5 4 3 2 1
Fig.4-4: J3 connector terminals and functions
Pin Signal name
Function
Section
1 2 3 4 5 6 7 8
Programmed Signal 1 General Purpose Open collector Port 1
5.7.3 5.7.4 8.5.2
PS_OK
Output for indication of the power supply status. High level is OK.
Trigger Out
Trigger output, positive true, pulse width: Min. 10usec
ILC
Enable /Disable the power supply output by dry-contact (short/open). 5.7.2
Shut Off (SO)
Input for shut off control of the power supply output.
5.7.1 5.7.3
Programmed Signal 2 General Purpose Open collector Port 2
IFC_COM Trigger In
Isolated interface, common.
CMOS level input for triggering power supply output. Positive edge, pulse width: Min. 10usec.
8.5.1
Table 4-4: J3 connector terminals and functions
53