160V to 650V Models The 160V to 650V models have four terminal wire clamp output connector. The two left terminals are positive outputs and the other two right terminals are the negative outputs.
The connector requirements are as follows: 1. Connector type: IC 2,5/ 4-G-5,08 (Phoenix). 2. Plug type: IC 2,5/ 4-ST-5,08 (Phoenix). 3. Wires: AWG16 to AWG24. 4. Tightening torque: 4.4-5.3 Lb-inch. (0.5-0.6Nm).
Follow the below instructions for connection of the load wires to the power supply: 1. Strip approx. 10mm at the end of each of the wires. 2. Loosen the mating connector terminal screws 3. Insert the stripped wires into the terminal and tighten the terminal screw securely (see Fig.3-4).
MALE CONNECTOR (IC 2,5/ 4-G-5,08 , PHOENIX CONTACT)
FEMALE PLUG (IC 2,5/ 4-ST-5,08, PHOENIX CONTACT) WIRES: COPPER, AWG 16~24 TIGHTENING TORQUE: 4.4-5.3 Lb-inch. (0.5-0.6Nm).
Fig.3-4: Load wires connection to the output plug.
4. Assemble the protective shield to the plug and tighten the screw to fix the shield to the plug (see Fig.3-5).
PT SCREW KA30X6 WN1412
Fig. 3-5: Plug shield mounting
WARNING: There is a potential shock hazardwhenusing a power supplywith an output voltage greater than 60VDC. Do not turn ON power supply when output voltage is above 60VDC without output plug protection assembled. Ensure that the protection of output plug is mounted and properly assembled, and that the plug protection is locked by PT type screw as described in Fig. 3.5