CHAPTER 10: ISOLATED ANALOG PROGRAMMING OPTION
10.1 Introduction Isolated Analog Programming is an internal option card for analog programming of the Z + Power Supply series. The option is factory installed and cannot be obtained with GPIB (IEEE) Interface. Output Voltage and Current Limit can be programmed and readback through optically isolated signals which are isolated from all other ground references in the power supply. There are two types of Isolated Analog programming cards: 1. 0-5V/0-10V option (PN: IS510): Using 0-5V or 0-10V signals for programming and readback. 2. 4-20mA option (PN: IS420): Using current signals for programming and readback. 10.2 Specifications 10.2.1 0-5V/0-10V Option (PN: IS510)
Output voltage programming accuracy Output current programming accuracy
% %
+/-1 +/-1
Output voltage programming temperature coefficient Output current programming temperature coefficient
PPM/ C +/-100 PPM/ C +/-100
Programming Inputs
Input impedance
Ohm 1M
Absolute maximum voltage
Vdc Vdc
0-15 650
Max. voltage between program inputs and supply outputs. (See Note 1)
Output voltage monitoring accuracy Output current monitoring accuracy
% %
+/-1.5 +/-1.5
Monitoring Outputs
Output Impedance (see Note)
Ohm 100
Max. voltage between monitoring outputs and supply outputs. (See Note 1) Vdc
650
NOTE: Use 100Kohmminimum input impedance for themonitoring circuits tominimize the readback error.
10.2.2 4-20mA Option (PN: IS420)
Output voltage programming accuracy Output current programming accuracy
% %
+/-1 +/-1
Output voltage programming temperature coefficient Output current programming temperature coefficient
PPM/ C +/-200 PPM/ C +/-200
Programming Inputs
Input impedance
Ohm 50
Absolute maximum input current
mA Vdc
0-30 650
Max. voltage between program inputs and supply outputs. (See Note 1)
Output voltage monitoring accuracy Output current monitoring accuracy
% %
+/-1.5 +/-1.5
Monitoring Outputs
Maximum load impedance
Ohm 500
Max. voltage between monitoring outputs and supply outputs. (See Note 1) Vdc
650
NOTE 1: Incaseof supplyoutput grounded (+or -) themax. voltagebetweenprograminputs andsupplyoutputs/ monitoring outputs and supply outputs should not exceed 400VDC. (Applicable for 10.2.1 and 10.2.2)
132