8.5 Trigger
Subsystem Level
Display Function Level
Display Parameter Level Display
Description
Initialization (Refer to command INIT) ready for trigger.
INIT
INIT
n
TRIG ENA
G
n
refer to command INIT:CONT
Continue
n
DIS
BUS (via Software or front Panel),
Trigger IN (input trigger)
refer to command TRIG:SOUR
Trigger Setting
G
EXT (Analog)
refer to command TRIG:DELAY. Fine and Course modes
Trigger delay
0-65sec
OFF
refer to command OUTP:TTLT:MODE
Trigger
Trigger OUT
G
Function Strobe
.
Refer to commands LIST:LOAD and WAVE:LOAD
LOAD List or Wave data
L1…L4
(Refer to LIST:COUN andWAVE:COUN) allow course and fine setting (Refer to LIST:STEP and WAVE:STEP)
COUNter (set repeat time)
1…9999
N
Programming
G
ONCE AUTO
STEP setting
ABORt execution
(Refer to command ABORt)
YES
Table 8-1: Trigger and Programming front panel menu
NOTE: At AC power ON the display shows last selected program list but dosen’t load it from memory. NOTE: If during program selection L1-L4, display shows ” ERR ” message then programmemory is empty or power supply is in initiated state. Select ”ABORt” to EXIT from initiate state. 8.5.1 Input Trigger Trigger source can be set via: • BUS - Command (Refer to section 7.11 *TRG, 7.12 TRIGger) or Front Panel. • EXT - Rear panel connector J3-8 (Refer to section 4.3.2). Input Trigger source setting via Front Panel: 1. Press MENU button. MENU (green) LED illuminates. ” set ” message appears on the Voltage display. 2. Rotate Voltage encoder until ” triG ” message appears on Voltage display. 3. Press Voltage encoder. ” ” message appears on Voltage display. 4. Rotate Voltage encoder until ” I ” message appears. Press Voltage encoder. 5. ” I ” message appears on Voltage Display and ” ” or ” ” messages appear on Current display. Rotate to scroll list and press Current encoder to select.