TDK Lambda | Z+High Voltage User Manual
8.3 LIST Mode Output change value in step determined by parameters in the LIST subsystem via input trigger. Refer to section 7.12.8
Fig.8-3: Simplified Models of LIST Mode
0.01sec
Trig Initated
INIT:IMM
WTG
(Wait Trigger)
Trigger Event
TDC
TRIG:DEL 0.02
0.02s
STS
(Step Started)
DWELL
LIST:DWELL 0.05,0.06,0.03
0.05s
0.06s
0.03s
STC
(Step Complited)
OPC
(Operation Complited)
OUTPUT VOLTAGE
LIST:VOLT 5,10,0
LIST STEP AUTO
Fig.8-4: LIST Mode Sequence example