TDK Lambda | Z+High Voltage User Manual

CURRent:MODE This command selects FIX, LIST, WAVE subsystems control over the power supply output current.

SCPI Command Syntax GEN Command Syntax

[SOURce]:CURRent:MODE

None

Parameters *RST Value Examples Query Syntax

NONE | FIXed | LIST | WAVE

NONE

CURR:MODE LIST CURR:MODE FIX

[SOURce]:CURRent:MODE? NONE | FIX | LIST | WAVE

Returned Parameters

CURRent:TRIGger Programs the pending triggered current level of the power supply. The pending triggered current level is a stored value that is transferred to the output terminals when a trigger occurs.

SCPI Command Syntax GEN Command Syntax

[SOURce]:CURRent[:LEVel]:TRIGger[:AMPLitude]

None

Default Suffix

A

Examples

CURR:TRIG 3200 MA CURR:LEV:TRIG 3.2

Query Syntax

[SOURce]:CURRent[LEVel]:TRIGger [:AMPLitude]?

CURR:TRIG? returns the presently programmed triggered level. If no triggered level is programmed, the CURR level is returned.

Returned Parameters

NOTE: CURR:MODE LIST and WAVE are an implied ABORt command. Only the last sent command can be accepted as WAVE or LIST. Previous mode reverts to NONE.

7.12.5 Measure Subsystem This subsystem reads the actual voltage and current. The power is a result of multiplying voltage and current measurements. MEASure:CURRent? Reads the measured output current. Returns a 6 digit string.

SCPI Command Syntax GEN Command Syntax

MEASure:CURRent?

MC?

Parameters

None

Default Suffix

A

Returned Parameters

105