TDK Lambda | Z+High Voltage User Manual

*OPC Operation Complete command. Sets the Operation Complete bit in the Standard Event Status Register if all commands and queries are completed.

Meaning and Type Command Syntax

Operation Complete

Device Status

*OPC None

Parameters

*OPC? Operation Complete query. Returns ASCII ‘1’ as soon as all commands and queries are completed.

Meaning and Type

Operation Complete

Device Status

Query Syntax

*OPC?

ASCII 1 is placed in the Output Queue when the power supply has completed operations.

Parameters

*OPT? The options (OPT) query returns a comma-separated list of all of the instrument options currently installed on the signal generator.

Parameter

Option

0 1 2 3

NONE

IEEE LAN

BOTH

Query Syntax

*OPT?

Returned Parameters

*PSC The Power-On Status Clear (PSC) command controls the automatic power-on clearing of the Service Request Enable Register, the Standard Event Status Enable Register, and device-specific event enable registers. • ON(1) - This choice enables the power-on clearing of the listed registers. • OFF(0) - This choice disables the clearing of the listed registers and they retain their status when a power-on condition occurs.

Meaning and Type Command Syntax

Power-on Status Clear Device Initialization

*PSC 0 | 1 | OFF | ON *PSC 0 *PSC 1

Parameters

Example

Query Syntax

*PSC?

Returned Parameters

0 | 1

96

Made with FlippingBook - professional solution for displaying marketing and sales documents online