5.6 Daisy-Chain Connection It is possible to configure a multiple power supply system to shut down all units when a fault condition occurs in one of the units. When the fault is removed, the system recovers according to a preset state: Safe start mode or Automatic restart. Set signal ” SO ” to positive logic via Front panel (refer to section 5.7.1) . If a fault occurs in one of the units it’s ”PS_OK”signal will be set to low level and the display will indicate the fault. The other units will shut off and their displays will indicate ” SO ”. When the fault condition is removed, the units will recover to their last setting according to their respective Safe start or Auto-restart setting. Fig.5-6 shows connection of three units, however the same connectionmethod applies to systems with more units.
POWE R S UP P LY #2
POWE R S UP P LY #3
POWE R S UP P LY #1
J 3-7
J 3-5
J 3-7
J 3-5
J 3-7
J 3-5
J 3-2
J 3-2
J 3-2
IFC _COM
P S _OK
IFC _COM
P S _OK
IFC _COM
P S _OK
S O
S O
S O
Fig.5-6: Daisy-Chain connection
5.7 Rear Panel (J3 Connector) Functions and Settings Subsystem Level Display Function Level Display Parameter Level
Display
Description
Enable/Disable interlock function (Analog ON/OFF) Positive (polarity) same as PS_OK signal
Enable (ON)
N
Interlock
Disable (OFF)
Positive
Shut OFF
Negative
Rear Panel
.
High
Programmed PIN 1
Open collector
Low
High
Programmed PIN 2
Open collector
Low
Table 5-3: Rear panel subsystem menu