10.3 Isolated Programming & Monitoring Connector Refer to Table 10-1 for detailed description of the Rear Panel Isolated Programming & Monitoring connector. To provide the lowest noise performance, it is recommended to use shielded-twisted pair wiring. Refer to Fig.10-1 for description of the connector. Isolated programming plug P/N: MC1.5/8-ST-3.81, Phoenix.
1 2 3 4 5 6 7 8
Shield
Shield
+VPROG_ISO
+IMON_ISO
+IPROG_ISO GND
+VMON_ISO GND
Fig.10-1: Isolated Programming & Monitoring connector
Range 0-5/0-10V IS510 option
Range 4-20mA IS420 option
Terminal
Signal name Function
Shield, connected internally to chassis of the supply.
1
SHLD
Chassis ground
+VPROG_ISO Output voltage programming input
0-5/0-10V
4-20mA
2
3
+IPROG_ISO Output current programming input
0-5/0-10V
4-20mA
4
GND
Ground for programming signals.
Ground
Ground
5
GND
Ground for programming signals.
Ground
Ground
6
+VMON_ISO Output voltage monitoring output
0-5/0-10V
4-20mA
7
+IMON_ISO Output current monitoring output
0-5/0-10V
4-20mA
Shield, connected internally to chassis of the supply.
8
SHLD
Chassis ground
Table 10-1: Detailed description of the Rear Panel Isolated Programming &Monitoring connector.
CAUTION: When the Isolated Analog Option is installed, do not apply any signals to the non-isolated VPGM and IPGM (J1-6 and J1-5) pins. All other J1 features may be used normally. Refer to Section 4.3.1 for a description of J1 features. Parallel operation: Optional Isolated Analog IS510/IS420 must be installed in both the Master and Slave units.