TDK Lambda | Z+Low Voltage User Manual
8.6.3Wave Execution via Front Panel
1. Load stored data MENU -> ” G ” -> ” ” -> 2. Set Trigger IN source ( BUS for Command or Front Panel and EXT via Rear Panel J3.8 pin) MENU -> ” G ” -> ” I ” -> ” ” 3. Set Trigger Initialize Continue mode (If 1 then after program execution power supply will be ready for the next trigger. If 0 then send INIT command MENU -> ” G ” -> ” on ” -> ” n ” to get to the next trigger. 4. Set INIT command. (Power supply ready for TRIGGER) MENU -> ” G ” -> ” ini ” -> ” ini ” 5. Exit from MENU and Press Current encoder to trigger.
8.7 Additional Examples 8.7.1 List Example TRIG:SOUR EXT
Select trigger source external analog signal
VOLT:MODE LIST
Select sequence mode ”LIST”
LIST:VOLT 2,4,2,8,5,4
Set voltage values ”2,4,2,8,5,4”Volts Set dwell values ”0.5,0.5,1,1,1,1” seconds
10
LIST:DWEL 0.5,0.5,1,1,1,1
8
LIST:COUN 1
Set list execution time ”1”
6
4
LIST:STEP AUTO INIT:CONT OFF
Set step execution mode ”AUTO” Trigger subsystem enabled for a single trigger action
Voltage [V]
2
0
0
1
2
3
4
5
Times [S]
INIT
Trigger initializing Trigger command
*TRG
8.7.2Waveform Example TRIG:SOUR BUS
Select trigger source via communication interface or front panel
VOLT:MODE WAVE
Select sequence mode ”WAVE”
10
WAVE:VOLT 2,2,4,4,9,9,3,3 Set voltage values ”2,2,4,4,9,9,3,3”Volts WAVE:TIME 0,1,0.5,0.5,0.5,0.5,1.5,1 Set time values ”0,1,0.5,0.5,0.5,0.5,1.5,1” seconds WAVE:COUN 2 Set wave execution time ”2” WAVE:STEP AUTO Set step execution mode ”AUTO” INIT:CONT ON Trigger system is continuously enabled INIT Trigger initializing *TRG Trigger command
8
6
4
Voltage [V]
2
0
0
1
2
3
4
5
6
Times [S]
NOTE: For an easy way to create arbitrary waveforms, you can use the ”Z + Waveform Creator” Application that can be downloaded from TDK-Lambda Technical Centre web page: https://www.emea.lambda.tdk.com/uk/technical-centre/software-tools.aspx (refer to Applications Guide, IA710-04-04_ for step-by-step installation procedure)