TDK Lambda | Z+Low Voltage User Manual
STATus
:OPERation
[:EVENt]?
Returns the value of the Event register Returns the value of the Condition register Enables specific bits in the Event register Returns the value of the Event register Returns the value of the Condition register Enables specific bits in the Event register
SEVE? STAT?
:CONDition
:ENABle
SENA[?]
:QUEStionable [:EVENt]?
FEVE?
:CONDition
FLT?
:ENABle
FENA[?]
SYSTem
:ERRor:ENABle
Enable error message
:ERRor?
Read system error messages Set communication language
:LANGuage GEN
:REMote
[:STATe] LOC|REM|LLO
Set the remote/local state Returns software revision Returns calibration date
RMT[?]
:VERSion?
REV?
:DATE?
DATE?
:PON
:TIME?
Response time from last reset
TRIGger
[:STARt]
Run trigger
:DELay
Set input trigger delay Set input trigger source
:SOURce EXTernal|BUS
Display Voltage and Current data. Data Reads the complete power supply status. Reset the added Fold Back Delay to zero.
STT?
FBDRST
Sets the Master/Slave parallel operation mode PMS[?]
Sets SO signal polarity
SOP[?]
Set factory default parameters
FRST
NOTES:
• •
• (*) – command UVP or UVL set protection or limit mode and level
118