TDK Lambda | Z+Low Voltage User Manual

TRIGger:SOURce Selects the power supply input trigger source as follows: • BUS (*TRG & TRIG) and Front Panel • EXT Mainframe backplane Trigger IN PIN SCPI Command Syntax TRIGger[:STARt]:SOURce GEN Command Syntax None Parameters BUS | EXTernal *RST Value EXTernal Examples TRIG: SOUR BUS Query Syntax TRIGger[:STARt]:SOURce? Returned Parameters BUS | EXT

7.12.12WAVE Subsystem This subsystem receives parameters to create a slopedwaveformof the output voltage or current. WAVE:COUNt Sets the number of times that the list is executed before it is completed. The command accepts parameters in the range 1 through 9999. Any number greater than 9999 is interpreted as INFinity. Use INF if you wish to execute a list indefinitely.

SCPI Command Syntax

[SOURce]:WAVE:COUNt

Parameters

1 to 9999 | INFinity

*RST

1

Examples

WAVE:COUN 3 WAVE:COUN INF

Query Syntax

[SOURce]:WAVE:COUNt? (if count>9999 the response is INF)

Returned Parameters

WAVE:CURRent This command specifies the output current points in a waveform list. The current points are given in the command parameters, which are separated by commas.

SCPI Command Syntax

[SOURce]:WAVE:CURRent {,}

Default Suffix

A

Examples

WAVE:CURR 2.5,3.0,3.5

up to 12 parameters

Query Syntax

WAVE:CURR?

Returned Parameters

WAVE:LOAD Loads Voltage or Current, Time, STEP parameter and counter values to a specific location in the memory defined by numbers <1..4>.

SCPI Command Syntax

[SOURce]WAVE:LOAD

Example

WAVE:LOAD 3

Query Syntax

none

Returned Parameters

1..4

113