LIST:VOLTage Specifies theoutput voltagepoints ina list.Thevoltagepoints aregiven in the commandparameters, which are separated by commas.
SCPI Command Syntax
[SOURce]:LIST:VOLTage
Default Suffix
V
Examples
LIST:VOLT 2.0,2.5,3.0 LIST:VOLT MAX,2.5,MIN
up to 12 parameters
Query Syntax
LIST:VOLT? 2.0,2.5,3.0
Returned Parameters
LIST:STORe Saves data under specified numbers <1..4> of the last LIST typed (voltage or/and current, dwell time, STEP parameter and counter).
SCPI Command Syntax
[SOURce]LIST:STORe
Example
LIST:STORe 3
7.12.9 STATus Subsystem Refer to Fig. 9-1 for more details. STATus:OPERation:EVENt?
This query returns the value of the Event register. This is a read-only register that receives data from the Condition register according to Enable register setting. Reading the Event register clears it.
SCPI Command Syntax GEN Command Syntax
STATus:OPERation:EVENt?
SEVE? None
Parameters
Returned Parameters
Examples
STAT:OPER:EVEN?
STATus:OPERation:CONDition? Returns the value of the Condition register, which is a read-only register that holds the real-time (unlatched) operational status of the power supply.
SCPI Command Syntax GEN Command Syntax
STATus:OPERation:CONDition?
STAT? None
Parameters
Returned Parameters
Examples
STAT:OPER:COND?