TDK Lambda | Z+Low Voltage User Manual

*RCL n Restores the power supply to a state previously stored in memory by *SAV command. Refer to Table 5-7.

Command Syntax

*RCL

Parameters

1 to 4 *RCL 3

Exmple

*RST This command resets the power supply to a defined state as shown in Table 5-7. *RST also forces an ABORt command.

Command Syntax

*RST None

Parameters

*SAV n The SAV command saves all applied configuration setting. Refer to Table 5-7.

Command Syntax

*SAV

Parameters Query Syntax

1 to 4 None

*SRE Service Request Enable command. Modifies the contents of the Service Request Enable Register.

Meaning and Type Command Syntax

Service Request Enable Device Interface

*SRE

Parameters Default Value

0 to 255 See *PSC *SRE 20

Example

Query Syntax

*SRE?

Returned Parameters

(Register binary value) 3digits

97