7.8.7 Auxiliary Commands
SOP
Sets SO polarity ”SO 1/ON” –Positive (default), ”SO 0/OFF”-Negative
SOP?
Returns the SO polarity
RIE
Remote Interlock (Inhibit) enable. ”RIE 1/ON”-Enable, ”RIE 0/OFF”-Disable” Returns Interlock enable status. ”ON” –interlock enable, ”OFF”-interlock disable.
RIE?
Factory reset command. This command cover *RST command and additional settings. Sets factory default. This command breaks communication. Refer to Table 5-7.
FRST
MP? REL1 REL1? REL2 REL2?
Reads the actual output power. Returns 5 digit string.
Set auxiliary programmed pin state J3-1. ”REL1 1/ON”- High, REL1 0/OFF”- Low
Response auxiliary programmed pin state J3-1.
Set auxiliary programmed pin state J3-6, ”REL2 1/ON”- High, REL2 0/OFF”- Low
Response auxiliary programmed pin state J3-6
7.8.8 Status Commands Refer to section 9.3.1, 9.3.2 for Register definitions.
#
Command Description
Reads the complete power supply status. Returns ASCII characters representing the following data, separated by commas: MV
1
STT?
2 3 4 5 6 7 8 9
FLT?
Reads Fault Conditional Register. Return 4-digit hex. Set Fault Enable Register using 4-digit hex. Reads Fault Enable Register. Returns 4-digit hex. Reads Status Conditional Register. Returns 4-digit hex. Sets Status Enable Register using 4-digit hex. Reads Status Enable Register. Returns 4-digit hex.
FENA FENA? FEVE? STAT? SENA SENA? SEVE?
Reads Fault Event Register. Returns 4-digit hex. Clears bits of Fault Event Register.
Reads Status Event register. Returns 4-digit hex. Clears bits of Status Event register.