7.1 Introduction This chapter describes the set-up, operation, commands and communicationprotocol of Z + power supplies via serial communication interfaces: RS232, RS485 or USB. 7.2 Configuration

Parameter Level

Function Level

Display

Display

Description



232

  

485 USB LAN IEEE

N

Interface

Available only if IEEE or LAN option installed

 1



Address

1….31





Baud Rate

1200..57600

SCP I

SCPI GEN



Language

G



   

IP Address

IP1---IP4

 

MAC Address

MAC1-MAC6

Available only if LAN option installed



LAN Reset

Yes

Table 7-1: Front panel setup

7.2.1 Default Setting Refer to Table 5-7: Memory parameters.

7.2.2 Address Setting The power supply address can be set to any address between 1 and 31.

1. Press REM button. The REM LED illuminates. ”  ” message appears on the Current display. 2. Press Current encoder. Voltagedisplay shows ”  ” andCurrent display shows present address. 3. Rotate the Current encoder to select required address. 4. Press Current encoder to enter selected parameter to memory. 5. When parameter is accepted the display blinks once and returns to the previous level. 7.2.3 Communication Interface Selection Z + power supply can be configured for RS232, RS485 or USB(*) communication interface. 1. Press REM button. The REM LED illuminates. ” N ” message appears on the Voltage display. 2. Press Voltage encoder. Voltagedisplay shows ” N ” andCurrent display shows communication interface. 3. Rotate the Current encoder to select the required interface. 4. Press Current encoder to enter selected parameter to memory. 5. When parameter is accepted the display blinks once and returns to the previous level. * Do not connect or disconnect the USB cable when the PS is operating.